01226 297711

Menu

Humiseal Polyurethane Conformal Coating details

Selecting the correct  Humiseal polyurethane conformal coating for your conformal coating application is often confusing and difficult with many factors to be considered. We understand this and have introduced this intuitive selector guide to help you through the specification process.

 

TDS
MSDS
1A68
1A20
1A33
2A64

Conformal Coating

No
Yes
Yes
Yes
Mil-I-46058C
Yes
Yes
Yes
Yes
IPC-CC-830
No
Yes
Yes
Yes
UL 764E
No
V0
V0
No
UL94
No
Pending
Yes
No
Aerosol available
47
50
44
39
Solids Content %
220
200
190
125
Viscosity Max (centipoise)
1
28
1
7
Flashpoint
521
425
521
576
VOC (grams/liter)
15 min
60 min
15 min
140 min
Drying time: tack-free
24 hrs
24 hrs
24 hrs
24 hrs
Drying time: Dry
1 month
24 hrs
1 month
24 hrs
Drying time: Cured
12 months
N/A
12 months
N/A
Pot life at RT
18 months
6 months
18 months
6 months
Shelf Life
18
20
18
16
Coverage m2/L (25um)
-65 to +125
Continuous Use Range °C
-65 to +125
Thermal Shock
26
71
26
18
Glass Transition T (Tg)
119
70
119
85
TCE x10-06 / °C Below Tg
225
183
225
201
TCE 10-06 / °C Above Tg
445
190
445
210
Elastic Modulus (Mpa)
3.60
3.50
3.60
3.50
Dielectric Constant
0.02
0.03
0.02
0.03
Dissipation Factor
60
60
60
60
DBV 1
>1500
>1500
>1500
>1500
DWV 2
200
300
200
170
Insulation Resistance 3
16
48
16
63
MIR 4
Good
Very Good
Good
Very Good
Chemical Resistance
1063, 1072
Recommended Stripper

1 Dielectric Breakdown Voltage, kV/mm @ 25C

2 Dielectric Withstand Voltage (1 Minute)

3 Insulation Resistance (106 Ohms)

4 Moisture Insulation Resistance ( 106 Ohms)

Disclaimer

All values contained herein are typical values. Please consult the Technical Data Sheet for the specific product to obtain complete information and detailed specification ranges and physical properties

Humiseal Conformal Coatings Acrylic REACH

Humiseal Conformal Coating REACH

RoHs Declaration

Humiseal Conformal Coating RoHs Declaration