Selecting the correct conformal coating for your conformal coating application is often confusing and difficult with many factors to be considered. We understand this and have introduced this intuitive selector guide to help you through the specification process.
N/A |
N/A |
TDS |
||||||||
MSDS |
||||||||||
1B12 |
1B31 |
1B31 EPA |
1B31 LOC |
1B66 |
1B73 |
1B73 EPA |
1B73 LOC |
1R32 |
1R32- A2 |
Conformal Coating |
No
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
No
|
Yes
|
Mil-I-46058C |
Yes
|
Yes
|
Yes
|
Yes
|
No
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
IPC-CC-830 |
No
|
No
|
No
|
No
|
No
|
Yes
|
Yes
|
Yes
|
No
|
Yes
|
UL 764E |
No
|
No
|
No
|
No
|
No
|
V0
|
V0
|
V0
|
No
|
V0
|
UL94 |
No
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
No
|
Yes
|
Aerosol available |
20.5
|
35
|
28
|
25
|
35
|
30
|
24
|
25
|
35
|
33
|
Solids Content % |
30
|
220
|
400
|
430
|
220
|
270
|
300
|
455
|
220
|
250
|
Viscosity Max (centipoise) |
1
|
1
|
12
|
22
|
1 |
1 |
30
|
22
|
1
|
1
|
Flashpoint |
680
|
592
|
684
|
91
|
685
|
644
|
730
|
92
|
680
|
690
|
VOC (grams/liter) |
10
|
10
|
20
|
25
|
10
|
15
|
25
|
25
|
10
|
10
|
Drying time: tack-free min |
24
|
24
|
24
|
24
|
24
|
24
|
24
|
24
|
24
|
24
|
Drying time: Dry hours |
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
Drying time: Cured weeks |
12
|
12
|
12
|
12
|
12
|
12
|
12
|
12
|
12
|
12
|
Pot life at RT (months) |
12
|
18
|
18
|
18
|
18
|
18
|
18
|
18
|
18
|
18
|
Shelf Life (months)
|
8
|
14
|
11
|
10.5
|
14
|
12
|
10
|
22
|
14
|
13
|
Coverage m2/L (25um) |
-65 to +125
|
Continuous Use Range °C | |||||||||
-65 to +125
|
Thermal Shock | |||||||||
52 |
14
|
14 |
14
|
15 |
44 |
44
|
42
|
15
|
20
|
Glass Transition T (Tg) |
185 |
189 |
189 |
189 |
193 |
193 |
193
|
193
|
185 |
184
|
TCE x10-06 / °C Below Tg |
335 |
330
|
330
|
330
|
338 |
338 |
338
|
338
|
335
|
333
|
TCE 10-06 / °C Above Tg |
350 |
170 |
170 |
170 |
180 |
180 |
180
|
180
|
350
|
175
|
Elastic Modulus (Mpa) |
2.8 |
2.5
|
2.5
|
2.5
|
2.6 |
2.6 |
2.6
|
2.6
|
2.5
|
2.5
|
Dielectric Constant |
0.01 |
0.01
|
0.01
|
0.01
|
0.01 |
0.01 |
0.01
|
0.01
|
0.01
|
0.01
|
Dissipation Factor |
60
|
60
|
60
|
60
|
59 |
60 |
60
|
60
|
56
|
58
|
DBV 1 |
>1500
|
>1500
|
>1500
|
>1500
|
>1500 |
>1500 |
>1500
|
>1500
|
>1500
|
>1500
|
DWV 2 |
250 |
600
|
600
|
600
|
550 |
550 |
550
|
550
|
585
|
598
|
Insulation Resistance 3 |
30 |
80
|
80
|
80
|
70 |
70 |
70
|
70
|
75
|
78
|
MIR 4 |
Poor
|
Poor
|
Poor
|
Poor
|
Poor |
Poor |
Poor
|
Poor
|
Poor
|
Poor
|
Chemical Resistance |
1080A |
1080A |
1080A |
1080A |
1080A |
1080A |
1080A
|
1080A
|
1080A
|
1080A
|
Recommended Stripper |
1 Dielectric Breakdown Voltage, kV/mm @ 25C
2 Dielectric Withstand Voltage (1 Minute)
3 Insulation Resistance (106 Ohms)
4 Moisture Insulation Resistance ( 106 Ohms)
Disclaimer
All values contained herein are typical values. Please consult the Technical Data Sheet for the specific product to obtain complete information and detailed specification ranges and physical properties
Humiseal Conformal Coatings Acrylic REACH
Humiseal Conformal Coating REACH
RoHs Declaration
Humiseal Conformal Coating RoHs Declaration